<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-09 14-31-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 55 dBuV P4 Norr
Pilot RDS Phase Difference
5.9 kHz 3.8 kHz -20 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 32 kHz 19000 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-4,6 dBr -2,46 dBr -0,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P4 Norr " E424 1 (News) 1 0 0 9 13:31, 9.04.2026
RT
"Ny ter P4 Norrbotten "
AF EON
101.9, 102.2, 102.9, 103.2 MHz E203, E201, E402
FM Scope Max at: 32 kHz MIN: 12 kHz % above 76 kHz: 0,0053 Acquired: 2026/04/09 14.30.41 Total samples: 19000 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,8 dBr MIN: -4,6 dBr AVE: -2,46 dBr % above 12,2 dBr: 0,0 Last value: -2,2 dBr (2026/04/09 14.30.41) 14.16 14.18 14.20 14.22 14.24 14.26 14.28 14.30 -4 -2 0 Pm [dBr]